MRFE6VP61K25NR6
晶体管, 射频FET, 133 V, 3.333 kW, 1.8 MHz, 600 MHz, OM-1230
Overview
These high ruggedness devices, MRFE6VP61K25N and MRFE6VP61K25GN, are designed for use in high VSWR industrial, medical, broadcast, aerospace and mobile radio applications. Their unmatched input and output design allows for wide frequency range use from 1.8 to 600 MHz.
MoreLess
## Features
* Unmatched Input and Output Allowing Wide Frequency Range Utilization
* Device can be used Single-Ended or in a Push-Pull Configuration
* Qualified Up to a Maximum of 50 VDD Operation
* Characterized from 30 to 50 V for Extended Power Range
* Suitable for Linear Application with Appropriate Biasing
* Integrated ESD Protection with Greater Negative Gate-Source Voltage Range for Improved Class C Operation
* Characterized with Series Equivalent Large-Signal Impedance Parameters
* RoHS Compliant
* This product is included in our product longevity program with assured supply for a minimum of 15 years after launch.
* Recommended drivers: AFT05MS004N 4 W or MRFE6VS25N 25 W
**Typical Applications**
* Broadcast
* FM broadcast
* HF and VHF broadcast
* Industrial, Scientific, Medical ISM
* CO2 laser generation
* Plasma etching
* Particle accelerators synchrotrons
* MRI
* Industrial heating/welding
* Aerospace
* VHF omnidirectional range VOR
* Weather radar
* Mobile Radio
* HF and VHF communications
* PMR base stations
## Features RF Performance Tables
### Typical Performance
VDD = 50 Vdc- .
- *Frequency
- .
- * | **Signal Type** | **Pout
- .
- * | **Gps
- .
- * | **ηD
- .
- *
\---|---|---|---|---
87.5-1081,2| CW| 1309 CW| 24.1| 77.6
2303| Pulse
100 µsec, 20% Duty Cycle| 1250 Peak| 23.0| 72.3
### Load Mismatch/Ruggedness
**Frequency
MHz- .
- * | **Signal Type** | **VSWR** | **Pin
- .
- * | **Test
- .
- * | **Result**
\---|---|---|---|---|---
2303 | Pulse
100 µsec,
20% Duty Cycle | > 65:1 at all
Phase Angles | 11.5 Peak
3 dB Overdrive | 50 | No Device
Degradation
1\\. Measured in 87.5-108 MHz broadband reference circuit.
2\\. The values shown are the center band performance numbers across the indicated frequency range.
3\\. Measured in 230 MHz narrowband test circuit.