MC100LVEL40DWG
MC100LVEL40: 相位 - 频率检测器,差分,ECL,3.3 V / 5.0 V
The MC100LVEL40 is a three state phase frequency-detector intended for phase-locked loop applications which require a minimum amount of phase and frequency difference at lock. Advanced design significantly reduces the dead zone of the detector. For proper operation, the input edge rate of the R and V inputs should be less than 5 ns. The device is designed to work with a 3.3 V power supply.When the reference R and the feedback FB inputs are unequal in frequency and/or phase the differential up U and down D outputs will provide pulse streams which when subtracted and integrated provide an error voltage for control of a VCO. pin, an internally generated voltage supply, is available to this device only. For single-ended input conditions, the unused differential input is connected to V as a switching reference voltage. V may also rebias AC coupled inputs. When used, decouple V via a 0.01 5F capacitor and limit current sourcing or sinking to 0.5 mA. When not used, VFor application information, see AND8040/D, "Phase Lock Loop Operation."The 100 Series Contains Temperature Compensation
Features
---
|
- .
- 250MHz Typical Bandwidth
- .
- ESD Protection: >2 KV HBM
- .
- PECL Mode Operating Range: VCC = 3.0 V to 5.5 V
with VEE = 0 V
- .
- NECL Mode Operating Range: VCC = 0 V
with VEE = -3.0 V to -5.5 V
- .
- Internal Input Pulldown Resistors
- .
- Meets or Exceeds JEDEC Spec EIA/JESD78 IC Latchup Test
- .
- Flammability Rating: UL-94 code V-0 @ 1/8",
Oxygen Index 28 to 34
- .
- Transistor Count = 356 devices
- .
- Pb-Free Packages are Available