UJA1061TW
容错CAN / LIN故障安全系统基础芯片 Fault-tolerant CAN/LIN fail-safe system basis chip
General description
The UJA1061 fail-safe System Basis Chip SBC replaces basic discrete components that are common in every Electronic Control Unit ECU with a Controller Area Network CAN and a Local Interconnect Network LIN interface. The fail-safe SBC supports all networking applications that control various power and sensor peripherals by using fault-tolerant CAN as the main network interface and LIN as a local sub-bus.
Features and benefits
General
■ Contains a full set of CAN and LIN ECU functions:
♦ CAN transceiver and LIN transceiver
♦ Voltage regulator for the microcontroller 3.3 V or 5.0 V
♦ Separate voltage regulator for the CAN transceiver 5 V
♦ Enhanced window watchdog with on-chip oscillator
♦ Serial Peripheral Interface SPI for the microcontroller
♦ ECU power management system
♦ Fully integrated autonomous fail-safe system
■ Designed for automotive applications:
♦ Supports 14 V, 24 V and 42 V architectures
♦ Excellent ElectroMagnetic Compatibility EMC performance
♦ ±8 kV ElectroStatic Discharge ESD protection Human Body Model HBM for off-board pins
♦ ±6 kV ElectroStatic Discharge ESD protection IEC 61000-4-2 for off-board pins
♦ ±60 V short-circuit proof CAN/LIN-bus pins
♦ Battery and CAN/LIN-bus pins are protected against transients in accordance with ISO 7637
♦ Very low sleep current
■ Supports remote flash programming via the CAN-bus
■ Small 6.1 mm × 11 mm HTSSOP32 package with low thermal resistance
CAN transceiver
■ ISO 11898-3 compliant fault-tolerant CAN transceiver
■ Enhanced error signalling and reporting
■ Dedicated low dropout voltage regulator for the CAN-bus:
♦ Independent from microcontroller supply
♦ Guarded by CAN-bus failure management
♦ Significantly improves EMC performance
■ Partial networking option with global wake-up feature, allows selective CAN-bus communication without waking up sleeping nodes
■ Bus connections are truly floating when power is off
■ Ground shift detection
LIN transceiver
■ LIN 2.0 compliant LIN transceiver
■ Enhanced error signalling and reporting
■ Downward compatible with LIN 1.3 and the TJA1020
Power management
■ Smart operating modes and power management modes
■ Cyclic wake-up capability in Standby and Sleep modes
■ Local wake-up input with cyclic supply feature
■ Remote wake-up capability via the CAN-bus and LIN-bus
■ External voltage regulators can easily be incorporated in the power supply system flexible and fail-safe
■ 42 V battery-related high-side switch for driving external loads such as relays and wake-up switches
■ Intelligent maskable interrupt output
Fail-safe features
■ Safe and predictable behavior under all conditions
■ Programmable fail-safe coded window and time-out watchdog with on-chip oscillator, guaranteeing autonomous fail-safe system supervision
■ Fail-safe coded 16-bit SPI interface for the microcontroller
■ Global enable pin for the control of safety-critical hardware
■ Detection and detailed reporting of failures:
♦ On-chip oscillator failure and watchdog alerts
♦ Voltage regulator undervoltages
♦ CAN and LIN-bus failures short-circuits and open-circuit bus wires
♦ TXD and RXD clamping situations and short-circuits
♦ Clamped or open reset line
♦ SPI message errors
♦ Overtemperature warning
♦ ECU ground shift two selectable thresholds
■ Rigorous error handling based on diagnostics
■ 23 bits of access-protected RAM is available e.g. for logging of cyclic problems
■ Reporting in a single SPI message; no assembly of multiple SPI frames needed
■ limp-home output signal for activating application hardware in case system enters Fail-safe mode e.g. for switching on warning lights
■ Fail-safe coded activation of Software development mode and Flash mode
■ Unique SPI readable device type identification
■ Software-initiated system reset