CLT01-38S4-TR
Digital Termination Array 38Pin HTSSOP T/R
CLT01-38S4 adds to the existing current limiter family. Still focusing on power consumption savings, the whole series allows each customer to find the right solution.
The CLT01-38S4 is an octal input termination device with a high speed SPI output. Its maximum input data rate is 400 kbps while the output SPI speed is 6.25 MHz.
As in previous versions, robustness is a key feature of CLT01-38S4. The product is compliant with surge standards defined in IEC 61000-4-x.
It can run all types of sensor according to IEC 61131-2. Type 1 and 3 with a 2.35 mA limited current and type 2 using two inputs per sensor with the correct RREF.
**Key Features**
- .
- 8-input circuit in common ground low side topology
- .
- Wide range input DC voltage VI : -30 V to 35 V
- .
- On state threshold: < 11 V with RI = 2.2 kΩ
- .
- Off state threshold: Iin > 1.5 mA or Vi > 5 V
- .
- Protected against -30 V reverse polarity
- .
- Typical ILIM = 2.1 to 2.6 mA adjustable current limiters
- .
- Tight current tolerance including temperature compensation: ±10%
- .
- Serial output with an SPI communication bus
- .
- Clock frequency up to 6.25 MHz
- .
- CPHA = CPOL = 0 bus master operation
- .
- Multi CLT operation in daisy chain connection
- .
- 16-bit mode: 8 bits for data / 8 bits for control
- .
- Minimum capture time: 4 μs
- .
- Input data rate: 200 kbps/100 kHz
- .
- Minimum propagation transfer time: 7 μs
- .
- 8-bit mode: 8 bits for data
- .
- Minimum capture time: 2.5 μs
- .
- Input data rate: 400 kbps/200 kHz
- .
- Minimum propagation transfer time: 4 μs
- .
- VCC = -0.3 to +35 V with RC = 2.2 kΩ
- .
- Ambient temperature range: -25 to +85°C
- .
- Digital inputs for programmable logic controller and decentralized I/O modules
- .
- Benefits
- .
- Enables input to meet type 1, 2 and 3 characteristics of IEC 61131-2 standard
- .
- Compatible operation with 2 wires proximity sensor according EN 60947-5-2 standard
- .
- Compact board with surface mount integration and reduced count of isolated couplers
- .
- Reduces the count of input-output of the bus controller circuit
- .
- Provides energy-less input LED visual status
- .
- Enhanced functional reliability
- .
- Built-in over voltage robustness and immune data transfer
- .
- Reduced dissipation: 78 mW max. per channel
- .
- Complies with following standards RI = 2.2 Ω, RC = 2.2 Ω, C = 33 nF:
- .
- Electrostatic discharge, IEC 61000-4-2:
- .
- ±8 kV contact discharge
- .
- ±15 kV air discharge
- .
- Electrical transient immunity IEC 61000-4-41:
- .
- FSCK= 6.25 MHz, ±3 kV
- .
- FSCK= 10 kHz, ±4 kV
- .
- Voltage surge IEC 61000-4-5
- .
- Input: ±15 kV
- .
- Power supply: ±2.5 kV