23-13-060-2
Transformer, Constant Voltage; 60VA; 60Hz; CVS Series; 6.94In.L; 4In.H; 9lbs.
Superior voltage regulation of ±1% sets the CVS Series apart from other power conditioning technologies on the market. Extremely tight regulation is accomplished by Sola/Hevi-Duty"s patented ferroresonant transformer technology. The CVS recreates a well regulated sinusoidal waveform that is well isolated from input disturbances including impulses, brownouts, severe waveform distortion, swells, and sags. No other power conditioning technology provides as complete a solution against these power quality disturbances. The CVS Series is ideal for applications where even a small amount of change in voltage level can lead to unscheduled downtime, mis-operation, incorrect data or scrapped production.- .
- * Specifications: Input: VA Ratings:** 30 to 7,500 VA. **Input Voltage Range:** +10/–20% of nominal. **Input Frequency:** 60 Hz. **Output: Voltage Regulation:** ±1% for an input line variation of +10/–20%. No loss of output for line loss of 3 mSec. **Overload:** Output collapses with overload; limits output current to a maximum of 2x rated current. **Output Harmonic Distortion:** 3% total RMS content at full load. **Harmonic Rejection:** Rejects severe waveform harmonics. **Noise Isolation:** 40 dB common and normal mode. **Surge Suppression:** Up to 6,000 Volt surges are suppressed to safe levels per ANSI/IEEE C62.41-1980 Class A and B waveforms. **Efficiency:** Up to 92% at full load. **Environmental Operating Temperature:** –20°C to +50°C. **Audible Noise:** 32 dBA to 65 dBA. **Approvals **Except as Indicated** **Listed to UL 1012; Certified to CSA C22.2, No. 66. **Warranty: **Ten-year limited warranty.
**Applications:**
* Industrial Automation and Control Equipment PLCs
* Marine Navigation Equipment
* Analytical Laboratory and Factory Automating Equipment
* Photographic Enlargers
* Photo Processing Equipment
* Closed-Circuit TV Transmission
* Sound/Recording Systems
**Features and Benefits:**
* Applications Requiring Precise Voltage Regulation Can Expect to Receive ±1% Output Regulation for Input Variation of +10 to –20%
* Protects Premise Wiring Since Non-Linear Loads Are Reflected Back to the Utility as Near Sinusoidal
* Safety Agency Approved: All CVSs Are UL Listed and CSA Certified
* Dual Function, Can Act as a Stepup or Stepdown Transformer in Addition to Providing Regulation
* Sinewave Output Even with a Distorted Source; Input Harmonics Are Eliminated
* Half-Load Input Voltage Range of +15 to –50% Input for +5, –10% Regulation