2026-30-C3LF
GDT 300V 20% 20kA THROUGH HOLE
Is your electrical equipment located in an outdoor structure? Then this gas discharge tube from Bourns will protect it from transient overvoltage events. Its DC sparkover voltage is 300 V with a tolerance of ±20%, and its impulse discharge current 8x20 us, 10 Hits is 10 A. This item should be stored between -40 °C and 90 °C. This GDT has an operating temperature range of -40 °C to 90 °C. It has 3 terminals/electrodes. The 2026-30-C3LF GDT has a radial termination style. This part has a lead diameter of 1 mm and a pitch of 4.75 mm. This product is 13 mm long, 11 mm tall and 7.9 mm deep.