R1.188.0960.0
SNO 4063K Safety Relay for Emergency Stop & Guard DoorApplicationsCan be used for emergency stop or guard door applications Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring Safety category 4 pursuant to EN 954-1 Stop category 0 pursuant to EN 60204-1 Manual or automatic start With / without cross circuit detection Control loop for monitoring external contactors 3 enabling paths, N/O force guided For processing signals of a light grid OSSD compatible pursuant to DIN EN 61496-1 LED displays for operating voltage, channel 1 and channel 2 Enclosure width 22.5 mm **Supply current circuit** | ---|--- Nominal voltage UN: | 24 VAC / DC or 230 VAC Nominal frequency: | 50 → 60 Hz Operating voltage range: | 0.85 → 1.1 x UN **Control circuit** | Response time tA1 S34: | 20 → 40 ms Response time tA2 S35: | 200 → 600 ms Fallback time tR K1, K2: | **Output circuit** | Contact assignment: | 3 NO Contact type: | Force guided Nominal switching voltage Un: | 240 VAC / 300 VDC Max. Continuous current In per current path: | 6A Max. total current of all current paths: | 12 A at 24 V / 8 A at 230 V Mechanical lifespan: | 10 x 106 **General data** | Connection type: | Screw terminals Protection rating enclosure / terminals: | IP40 / IP20 Dimensions H x W x D: | 96.5 x 22.5 x 114 mm Weight: | 210 g Ambient temperature: | -25 °C → +55 °C ### 认可 CE, BG, GS, UL, CSA, CCC### 标准 EN 954-1, EN 60204-1, EN 61496-1### 安全继电器
SNO 4063K Safety Relay for Emergency Stop & Guard DoorApplications
Can be used for emergency stop or guard door applications
Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring
Safety category 4 pursuant to EN 954-1
Stop category 0 pursuant to EN 60204-1
Manual or automatic start
With / without cross circuit detection
Control loop for monitoring external contactors
3 enabling paths, N/O force guided
For processing signals of a light grid OSSD compatible pursuant to DIN EN 61496-1
LED displays for operating voltage, channel 1 and channel 2
Enclosure width 22.5 mm
**Supply current circuit** |
---|---
Nominal voltage UN: | 24 VAC / DC or 230 VAC
Nominal frequency: | 50 → 60 Hz
Operating voltage range: | 0.85 → 1.1 x UN
**Control circuit** |
Response time tA1 S34: | 20 → 40 ms
Response time tA2 S35: | 200 → 600 ms
Fallback time tR K1, K2: | <25 ms
**Output circuit** |
Contact assignment: | 3 NO
Contact type: | Force guided
Nominal switching voltage Un: | 240 VAC / 300 VDC
Max. Continuous current In per current path: | 6A
Max. total current of all
current paths: | 12 A at 24 V / 8 A at 230 V
Mechanical lifespan: | 10 x 106
**General data** |
Connection type: | Screw terminals
Protection rating enclosure / terminals: | IP40 / IP20
Dimensions H x W x D: | 96.5 x 22.5 x 114 mm
Weight: | 210 g
Ambient temperature: | -25 °C → +55 °C
### 认可
CE, BG, GS, UL, CSA, CCC
### 标准