2814841
MCR-SL - 无源隔离器,具有安全隔离电化隔离,无需额外辅助电源 安全隔离,符合 EN 61 010 标准 电流信号 0 → 20 mA 或 4 → 20 mA 用于控制电子装置和过程外围设备之间的电气绝缘 **Input** | ---|--- Input signal: | 04 to 20 mA Loss voltage: | 2.5 V at I = 20 mA max. Input current/overload: | 50 mA / 100 mA max. Input voltage/overload: | 30 V / 30 V Voltage limitation | with Zener diode: | 33 V ±5% **Output** | Output signal: | 04 to 20 mA max. Output signal: | max. Load: | 1375 Ω at I = 20 mA- | Output signal Ripple: | eff Transmission error: | | 0.1% of final value ---|---|--- Additional faults per 100 Ω load: | | 0.02% of the measured value Temperature coefficient: | | ≤0.002%/K of measured value/100 Ω load Cut-off frequency 3 dB: | | Step response 10 to 90%: | | 5 ms at 500 Ω load Test voltage: | Input/Output | 4 kV ac Protection against dangerous shock currents secure separation: | | Reinforced insulation according to DIN EN 61 010 part 1 and secure | | Separation according to VDE 0100, Part 410 within the meaning of VDE 0106, Part 101 to | | 300 V ac/dc for overvoltage category II and degree of pollution | | 2 between all isolating distances Ambient temperature range: | | -10 °C → +70 °C Electromagnetic compatibility: | | CE compliant with EMC Directive 89/336/EEC \- Radiated interference: | | EN 50 081-1 \- Interference immunity | | EN50 082-2 ### Phoenix Contact DIN 卡轨安装外壳材料:聚酰胺 - 所有类型
**MCR-SL - passive isolator with secure isolation**
**Featured List:**
* Galvanic isolation without additional auxiliary power
* Secure isolation in accordance with EN 61 010
* Current signals 0 to 20 mA or 4 to 20 mA
* For electrical isolation between control electronics and process peripheral equipment
得捷:
LOOP POWERED ISOLATOR 4-20MA
欧时:
MCR-SL - 无源隔离器,具有安全隔离电化隔离,无需额外辅助电源 安全隔离,符合 EN 61 010 标准 电流信号 0 → 20 mA 或 4 → 20 mA 用于控制电子装置和过程外围设备之间的电气绝缘 **Input** | ---|--- Input signal: | 04 to 20 mA Loss voltage: | 2.5 V at I = 20 mA max. Input current/overload: | 50 mA / 100 mA max. Input voltage/overload: | 30 V / 30 V Voltage limitation | with Zener diode: | 33 V ±5% **Output** | Output signal: | 04 to 20 mA max. Output signal: | max. Load: | 1375 Ω at I = 20 mA- | Output signal Ripple: | eff Transmission error: | | 0.1% of final value ---|---|--- Additional faults per 100 Ω load: | | 0.02% of the measured value Temperature coefficient: | | ≤0.002%/K of measured value/100 Ω load Cut-off frequency 3 dB: | | Step response 10 to 90%: | | 5 ms at 500 Ω load Test voltage: | Input/Output | 4 kV ac Protection against dangerous shock currents secure separation: | | Reinforced insulation according to DIN EN 61 010 part 1 and secure | | Separation according to VDE 0100, Part 410 within the meaning of VDE 0106, Part 101 to | | 300 V ac/dc for overvoltage category II and degree of pollution | | 2 between all isolating distances Ambient temperature range: | | -10 °C → +70 °C Electromagnetic compatibility: | | CE compliant with EMC Directive 89/336/EEC \- Radiated interference: | | EN 50 081-1 \- Interference immunity | | EN50 082-2 ### Phoenix Contact DIN 卡轨安装外壳材料:聚酰胺 - 所有类型
艾睿:
MCR loop-powered isolator for the electrical isolation of current signals without auxiliary power, input signal:04 to 20 mA, output signal: 04 to 20 mA
Allied Electronics:
Isolator, Loop-Powered, Current Signals, 0-20mA, Screw Connection
Verical:
MCR loop-powered isolator for the electrical isolation of current signals without auxiliary power, input signal:04 to 20 mA, output signal: 04 to 20 mA
Online Components:
MCR Loop-Powered Isolator for the Electrical Isolation of Current Signals without Auxiliary Power
Electro Sonic:
MCR Loop-Powered Isolator for the Electrical Isolation of Current Signals without Auxiliary Power