ICB2FL02G
智能镇流器控制IC,适用于荧光灯镇流器 Smart Ballast Control IC for Fluorescent Lamp Ballasts
Description:
The 2nd Generation Smart Ballast Control IC integrates all functions required to operate FL lamps such as preheat-, ignition- and run-mode and protection features. Digital mixed-signal power control is employed enabling speedy, cost-effective and stable ballast designs with a minimum number of external components. Reliable and robust high voltage isolation is achieved using ’s proprietary Coreless Transformer Technology CLT. The ICB2FL02G is functionally similar to the ICB2FL01G with a number of optimizations to operating frequencies and detection thresholds for dimmable ballast designs.
Summary of Features:
- .
- Integrated critical conduction mode PFC stage with enhanced dynamic PFC performance over wide load range
- .
- Intelligent digital-/mixed-signal lamp inverter control
- .
- Integrated high-voltage level-shift half-bridge driver
- .
- Optimized for dimmable FL/CFL ballasts
- .
- Drives up to 4 lamps with few external components required
- .
- Built-in protection functions such as Over-Voltage Protection OVP and Over-Current Protection OCP
- .
- Adjustable end-of-life detection in multi-lamp topologies and detection of capacitive mode operation
- .
- Able to handle lamp chokes with high saturation behavior
- .
- Special in-circuit test mode for faster test time
- .
- Parameters set with resistors only
- .
- Separate adjustable levels of lamp overload and rectifier effect detection EoL1, EoL2
- .
- Intelligent discrimination between surge and half-bridge overcurrent events
- .
- Self-adapting dead time adjustment of the half-bridge driver
- .
- Highly accurate timing and frequency control over wide temperature range -25 to 125 °C
Benefits:
- .
- Reduced BOM cost by optimized lamp choke size
- .
- Halving the time for key tests such as end-of-life detection and preheat/operation modes
- .
- Reduced system cost and improved ballast stability
- .
- Suitable for dimming & multi-power ballasts
- .
- Enables ballast compatibility with a wider range of lamp types
- .
- Lamp can automatically restart following surge events and handle correctly EOL events
- .
- Eases design of multi-power ballasts and reduces EMI
- .
- Reliable, stable ballast designs