3412
FUSES/Non resettable fuses
Additional technical data
Ambient temperature max. Ta –55 °C to +90 °C
Recommended continuous operatingcurrent at 23°C 0,7 . In
Climatic category 55/090/21 according to IEC 60068-1
Solderability Reflow- soldering 235 °C, 2 sec. 215 °C, 3 sec. according to IEC 60068-2-58
Soldering heat resistance 260 °C, 10 sec.,
Fuse-link temperature rise ≤ 75 K UL/CSA trackwidth: 5 mm
according to IEC 60068-2-58
mperaturerhöhungen am Si-Einsatz ≤ 75 K UL/CSA according to IEC 60127-4
Storage temperature max. 40 °C at 70% r. H. / r. F.
Materials Housing Glass epoxy, flammability class UL94V-0 inals / Cu / Sn
Net weight pieces % 0,12 g